Magic Mailing List |
|
From: Jeff Sondeen (sondeen AT ISI DOT EDU) Date: Mon Aug 05 2002 - 12:22:42 EDT
bindu madhavan writes: > Hi, > I am seeing the following problem with extraction of > mosfet perimeter values extracted in magic-7.1.x > both from the magic-7.1.2 distribution and the CVS > repository as of July 10, 2002. > The problem is independent of tech file, > and observed on the following platforms: HP > workstation running HPUX 11.0, magic ported to cygwin > on i686 platform) > > Problem statement (ext_problem.txt in attched gz file): magic-7.1.x > extraction has incorrect PD and PS values for NMOS, PMOS > transistors, when there is more than one rectangle involved in the > description of the shape of diffusion -- for example: diffusion > contact, or right-angle turn of diffusion. > > Problem does not exhibhit itself in magic-65. > if a fix is too difficult (ie. have to identify and remove common edges from perimeter sums), can't the extract code just use the old method, which i think just solves for equivalent height and width from the area sum? /jeff
|
|