From: Mikael Sahrling (sahrling AT pacbell DOT net) Date: Thu Mar 29 2001 - 19:55:12 EST
"Jeff W. Sondeen" wrote: > > Mikael Sahrling writes: > > > > 2) input/output stream. One of the technologies we're working with have > > a > > grid-size of 0.025 microns. This will not work with the cifinput/output > > scale of centimicrons. Instead I changed the cif/calma source code to > > support > > millimicrons instead. My suggestion is to change the scale to > > millimicrons. > > however, my understanding is that CIF format by definition must be in > a scale of .01um. also, calma (GDS) is supposed to be .001 um but i > think that's a convetion. This could be, I always use calma format ... . If this is true the technology we're using (0.025 microns grid) is incompatible with CIF. Maybe one could have a setting such that if calmaonly is used in the cifinput/output section the scale is in millimicrons ... ? Mikael > > > 5) cell selection. I haven't been able to figure out how to select all > > cells > > of a certain kind. If I have 50 cells named, cell_0 ... cell_49 and > > I'd like to select them all I have to click all of them individually. > > I'd > > like to have some kind of wild-card input so you can type: "sel cel > > 'cell_*'" > > and get all of them selected. > > i hacked my local magic copy to do this, but it comes bundled with > other more idiosyncratic hacks, so will ask Rajit about a new 'branch' > on his cvs root.... Rajit, are you going to handle magic branches? > > /jeff
|
|