From: cfk (cfk AT pacbell DOT net) Date: Sun Sep 28 2003 - 11:20:24 EDT
Dear Graham: Its the contact metal that is the problem, not ,for instance, the metal connecting Vdd to the PFET. In the upper right corner of iv1v0x05 is a contact at your excel spread sheet coordinates 66-67 vertically and 18-19 horizontally. That is the first of the DRC issues. Each of your contacts has a similar issue with DRC. That begs the question of whether or not its the technology file or the invertor. For that one, I would have to defer to Tim, Jeff Sondeen and others. All I can tell you is that the metal in the middle of each contact is 2 lambda wide by 2 lambda hi and the DRC contends it violates rules 7.1 & 7.2. It looks like this is of type 'genericcontact' if that helps any further. The other thing to keep in mind is that I am using the SCN6M_DEEP.09 technology file for the 0.18um measurements and the SCN5M_DEEP.12 technology file for the 0.25um measurements. In both cases, the DRC errors are in the same places. There are a total of 14 of them and they are equally spread between 7.1 & 7.2. Charles From: "Graham Petley" <graham.petley AT vlsitechnology DOT org> To: <magic-dev AT csl DOT cornell.edu> Sent: Saturday, September 27, 2003 11:21 PM Subject: Re: Magic standard cell library available > Hallo Charles, > The metal should be 4 lambda wide and 4 lambda spacing. I > looked at the cell in Magic and it was twice the width of the > poly, which is 2 lambda wide. I also looked at the original CIF > in Alliance Dreal and the metal was 4um wide. I think that if > there was some scaling error reading the CIF into magic, there > would be many other DRC errors apart from the metal! > Best Regards, Graham Petley > --- cfk <cfk AT pacbell DOT net> wrote: > > I have been working this morning with Graham's library and I > > have a couple > > of observations and a couple of questions. > > > > The first observation is that in working with his cell > > iv1v0x05.mag which is > > the smallest and simplest cell. I seem to have DRC errors for > > "metal1 width" > > and "metal1 spacing". These are mosis rules 7.1 and 7.2. I am > > using two > > different technology files. The first is > > "SCN5M_DEEP.12.tech27" and the > > second one is "SCN6M_DEEP.09.tech27". These are the .25um and > > .18um tech > > files, that near as I can tell are most appropriate for .25um > > and .28um > > designs at this time. > > > > They both say the metal1 spacing and metal1 widths need to be > > 3 lambda and > > they are 2 lambda in the cells themselves. I cant tell if > > this is a cell > > issue or a technology file issue and would appreciate some > > guidance. > > > > My questions relate to the technology files themselves. > > > > 1. Is "Is SCN5M_DEEP.12.tech27" the appropriate technology > > file for .25um > > studies?" > > 2. Is "Is SCN6M_DEEP.09.tech27" the appropriate technology > > file for .18um > > studies?" > > 3. What is the appropriate technology file for .13um studies? > > 4. What is the appropriate technology file for .09um studies? > > > > I want to comment Graham for his effort to get as far as he > > has. I think > > trying to create a library that is scalable between .25um, > > .18um, .13um and > > .09um is a marvelous thing and I want to understand and help > > as much as > > possible. > > > > Charles > > > > > > ===== > Graham Petley > ASIC Specialist and Consulting Engineer > Metzstrasse 14, 81667 Munich, Germany > Phone +49-89-6349-7630 Mobile +49-177-282-5072 > http://www.vlsitechnology.org/
|
|